Friday, May 5, 2017

Replies to Zos messages


http://narkive.com/OTIqXkPg:3.637.2

Issue is how to reply to messages.  

IXC208I THE RESPONSE TO MESSAGE IXC420D IS INCORRECT: IS NOT A VALID ACTION
IXC420D REPLY I TO INITIALIZE SYSPLEX ADCDPL, OR R TO REINITIALIZE XCF.
REPLYING I WILL IMPACT OTHER ACTIVE SYSTEMS.
I
IEE282A REPLY 00 EXPECTED; NO OTHER COMMANDS ACCEPTED. SPECIFY
REPLY 00.
All replies to messages in z/OS (and other versions of MVS) are done with
the reply command. The command is issued as "R <id>,<text>", where <id> is
the reply ID printed next to the message and <text> is the text of the
reply. There's no reply ID shown next to this message because the reply ID
at NIP time (before the full console display is redrawn) is always 00. That
means you need to enter the command as "R 00,'I'" (without the "").